I am a BIG BBC Radio 4 BBC Radio 4 PM fan, seriously! So delighted to be on PM today with Evan Davis discussing - you guessed it - flow temperatures! Tune in, if you're not already of course 👇 bbc.co.uk/sounds/play/li…

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

A little confusion over the 'e' setting on flow temperature dials. It's quite a high temperature and we recommend ignoring it and setting the dial to the 12 o'clock position. ALSO not to be confused 'eco mode' On WB boilers, which is turning off the pre-heat for hot water.

Richard Burrows (@richmwphs) 's Twitter Profile Photo

Really enjoyed this episode on Priority Domestic Hot Water and Modulation Controls with Nath! 🤓 If you’ve not listened to BetaTalk - Renewable Heating Podcast before, it’s well worth a listen and also to the previous seasons about all things going on in the heating industry! 😎👌🏻👍🏻 #PDHW #TwoFlowTemps

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

You can now download our free PDF flyer on lowering the flow temperature on your condensing combi boiler directly from our site, via this link: theheatinghub.co.uk/mission

You can now download our free PDF flyer on lowering the flow temperature on your condensing combi boiler directly from our site, via this link:
theheatinghub.co.uk/mission
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

Why is solar PV not mandatory for new build homes? When I do see some panels on a new development, it doesn't cover the roof. It is a suggestion of sustainability, a nod, the bare minimum. Why aren't new homes all designed with south facing roofs? Easy wins missed time & again

Why is solar PV not mandatory for new build homes?

When I do see some panels on a new development, it doesn't cover the roof. It is a suggestion of sustainability, a nod, the bare minimum.

Why aren't new homes all designed with south facing roofs?

Easy wins missed time & again
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

The new climate advisor to Liz Truss has advised investors to back renewables over fracking; calling it at "non-starter". Some hope. I was actually starting to miss Boris. ft.com/content/481b67…

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

Energy prices are rising today to 10.3p per kWh gas & 34p per kWh electricity. NB If you use more than 12,000kWh gas & 3,100kWh electricity you will pay more than £2,500 pa. Our latest blog summaries the easy wins for reducing your heating bill. 🧵1/9 theheatinghub.co.uk/articles/quick…

Energy prices are rising today to 10.3p per kWh gas & 34p per kWh electricity.

NB If you use more than 12,000kWh gas & 3,100kWh electricity you will pay more than £2,500 pa.

Our latest blog summaries the easy wins for reducing your heating bill. 🧵1/9

theheatinghub.co.uk/articles/quick…
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

In what credible 'best buy' list is the Hive control - which cannot vary a boiler's flow temperature or kW output - awarded 'Best Overall' smart thermostat? It turns boilers on/off, technology that went out with non-condensing boilers. More useless content diyworks.co.uk/best-smart-the…

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

Bad advice wastes your budget: Cost to remedy works caused by a rogue gas engineer £1,883 TheCIPHE Cost to fit a new boiler under 15 yrs old £2,500 - £5,000 v fixed price repair @ £300 10 years of boiler inefficiency: £1,467 Good advice saves you £££ theheatinghub.co.uk

Bad advice wastes your budget:

Cost to remedy works caused by a rogue gas engineer £1,883 <a href="/CIPHE/">TheCIPHE</a>

Cost to fit a new boiler under 15 yrs old £2,500 - £5,000 v fixed price repair @ £300

10 years of boiler inefficiency: £1,467

Good advice saves you £££

theheatinghub.co.uk
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

We're delighted to partner with Nesta to help households save £ this winter 113,000 people have turned down the flow temperature on their combi boiler to save c£112 Stand in front of your boiler & click this link for easy step by step instructions: moneysavingboilerchallenge.com

We're delighted to partner with <a href="/nesta_uk/">Nesta</a> to help households save £ this winter

113,000 people have turned down the flow temperature on their combi boiler to save c£112

Stand in front of your boiler &amp; click this link for easy step by step instructions:
moneysavingboilerchallenge.com
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

Boiler oversizing is a near universal malpractice. It reduces efficiency by 6-9%, which is as bad as high flow temperatures & on/off controls. Typical heat loss for UK homes is 6-10kW. Its now mandatory for boiler installers to carry out a heat loss calculation. Ask for a copy!

Boiler oversizing is a near universal malpractice. It reduces efficiency by 6-9%, which is as bad as high flow temperatures &amp; on/off controls. Typical heat loss for UK homes is 6-10kW. Its now mandatory for boiler installers to carry out a heat loss calculation. Ask for a copy!
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

What size boiler do I need? What temperature should my heating be set at? Which controls are the most efficient? Where might I be wasting gas? Tricky topics, that can all start with 'it depends on' but just knowing the rights Qs is a good place to start. theguardian.com/money/2022/dec…

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

If you're housebound due to snow & can't afford to heat your home > Heat one room & the bedroom before bed. Do this via the boiler if you have thermostatic radiator valves >Still turn down the flow temperature on a combi (below) >Stop draughts under doors moneysavingboilerchallenge.com

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

EPC fun facts: >You get extra points for weather compensation controls & 45°C flow temps, not both >ASHPs carry the same value as a new gas boiler due to energy cost metric Net Zero Performance Cert desperately needed to recognise carbon reduction as well as energy efficiency.

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

Thrilled to announce our merger with tech start-up Warmur We’ve spent 3 yrs pioneering personalised heating advice & building a network of top-tier installers This merger is a huge step towards scaling our services & making the transition easier & fairer for all 🧵

Thrilled to announce our merger with tech start-up <a href="/warmurhome/">Warmur</a>

We’ve spent 3 yrs pioneering personalised heating advice &amp; building a network of top-tier installers

This merger is a huge step towards scaling our services &amp; making the transition easier &amp; fairer for all 
🧵
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

24% households are actively looking for advice on off-peak tariffs, energy efficient home upgrades or accessing grants Impartial & expert advice maximises consumer budgets by identifying the biggest energy saving measures & avoiding bad buying decisions👇 installeronline.co.uk/the-heating-hu…

Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

It's been a crazy, wonderful week with so much warmth received for the news of our merger Warmur, TQ! We end the week celebrating the 3rd anniversary of launching the Heating Hub. 3 yrs of impartial advice on home heating🥳 And we're so looking forward to the next chapter!

It's been a crazy, wonderful week with so much warmth received for the news of our merger <a href="/warmurhome/">Warmur</a>, TQ!

We end the week celebrating the 3rd anniversary of launching the Heating Hub. 3 yrs of impartial advice on home heating🥳

And we're so looking forward to the next chapter!
Jo Alsop, Warmur (@theheatinghub) 's Twitter Profile Photo

A householder on #youandyours BBC Radio 4 was advised that he needed two large heat pumps to replace his 30kW boiler + 3 phase supply Boiler outputs are not representative of a home's heat requirement. He likely needed one 12-14kW heat pump 25 mins in 👇 bbc.co.uk/sounds/play/m0…